Search results for "Maximum intensity"

showing 10 items of 15 documents

A Novel Bio-Inspired Approach for High-Performance Management in Service-Oriented Networks

2021

Service-continuity in distributed computing can be enhanced by designing self-organized systems, with a non-fixed structure, able to modify their structure and organization, as well as adaptively react to internal and external environment changes. In this paper, an architecture exploiting a bio-inspired management approach, i.e., the functioning of cell metabolism, for specialized computing environments in Service-Oriented Networks (SONs) is proposed. Similar to the processes acting in metabolic networks, the nodes communicate to each other by means of stimulation or suppression chains giving rise to emergent behaviors to defend against foreign invaders, attacks, and malfunctioning. The mai…

maximum intensity projectionPerformance managementComputer sciencebio-inspired networksDistributed computingbio-inspired networks FPGA technology high-performance management Service-oriented networksbio-inspired networks; biomedical imaging; cerebral vascular tree reconstruction; FPGA technology; high-performance management; magnetic resonance angiography; maximum intensity projection; Service-oriented networksSoftwareGate arrayRobustness (computer science)Factor (programming language)Computer Science (miscellaneous)ArchitectureField-programmable gate arrayhigh-performance managementcomputer.programming_languagebusiness.industrymagnetic resonance angiographyComputer Science ApplicationsHuman-Computer InteractionTree (data structure)FPGA technologycerebral vascular tree reconstructionbiomedical imagingService-oriented networksbusinesscomputerInformation SystemsIEEE Transactions on Emerging Topics in Computing
researchProduct

CT-Angiographie bei arterieller Verschlußkrankheit: Vergleich von 3 Rekonstruktionsverfahren

1997

Purpose To evaluate different rendering techniques of CT data for the assessment of long vessel segments in peripheral vascular occlusive disease. Material and methods 40 CT angiograms (aortoiliac: n = 20, leg arteries: n = 20) were viewed using three different rendering techniques: 1, maximum intensity projection (MIP); 2, volume rendering (VR); 3, shaded surface display (SSD). CT angiograms were obtained in 6 or 8 projections. Axial cross-section images were analysed using an interactive cine mode. Intraarterial DSA was the standard in all cases. Results The sensitivities for the diagnosis of occlusive disease were 100% (cross-section images), 94% (MIP), 91% (VR) and 93% (SSD). The specif…

medicine.medical_specialtymedicine.diagnostic_testbusiness.industryVascular diseaseVolume renderingIterative reconstructionmedicine.diseaseRendering (computer graphics)Maximum intensity projectionArterial Occlusive DiseasesAngiographyMedicineRadiology Nuclear Medicine and imagingRadiologyTomographybusinessRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Stratosphere–troposphere exchange (STE) in the vicinity of North Atlantic cyclones

2015

Atmospheric Chemistry and Physics, 15 (19)

Maximum intensityAtmospheric ScienceGeopotential heightStormAtmospheric scienceslcsh:QC1-999lcsh:ChemistryTropospherelcsh:QD1-999ClimatologyExtratropical cycloneCycloneTropopauseStratospherelcsh:PhysicsGeologyAtmospheric Chemistry and Physics
researchProduct

Non-invasive diagnosis in a case of bronchopulmonary sequestration and proposal of diagnostic algorhythm

2008

The case of a 43-year-old woman with intralobar pulmonary sequestration, Pryce type one, is presented. The medical history was characterised by recurrent bronchopneumonia, productive cough with purulent sputum and hemoptysis in the last three years. Diagnosis was made by CT angiography: multiplanar, maximum intensity projection and volume rendering reconstructions were visualised. A volume reduction of middle and lower lobe with multiple cyst-like bronchiectasis was detected and no evident relationship with tracheobronchial tree was pointed out. Reconstructions aimed at evaluating bronchial structures demonstrated no patency of middle and lower lobar bronchi. The study carried out after con…

AdultPulmonary and Respiratory Medicinemedicine.medical_specialtylcsh:MedicinePulmonary sequestrationmedicine.arterymedicineHumansThoracic aortaBronchopulmonary sequestrationBronchopulmonary sequestrationBronchiectasismedicine.diagnostic_testbusiness.industryDecision Treeslcsh:RLung imagingmedicine.diseaseContrast mediumCT angiographyMaximum intensity projectionAngiographyVascular DisorderFemaleRadiologyCardiology and Cardiovascular MedicinebusinessAlgorithmsMonaldi Archives for Chest Disease
researchProduct

Salt and fat contents influence the microstructure of model cheeses, chewing/swallowing andin vivoaroma release

2013

The effects of the lipid/protein ratio (20/28, 24/24, 28/20) and salt content of model cheeses were investigated simultaneously with respect to chewing behaviour, swallowing events and in vivo aroma release. Chewing parameters were measured by electromyography. Swallowing events were recorded manually. In vivo aroma release was investigated using nose-space on-line atmospheric pressure chemical ionisation-mass spectrometry. The values for chewing activity and time before swallowing were higher with lower lipid/protein ratios and lower salt contents, due to the greater mechanical resistance of the model cheeses. The corresponding microstructure was made up of smaller and more circular fat dr…

chemistry.chemical_classificationMaximum intensitybiologyChemistrydigestive oral and skin physiologyfood and beveragesSalt (chemistry)General ChemistryMechanical resistancebiology.organism_classificationMicrostructurestomatognathic systemSwallowingIn vivoComposition (visual arts)Food scienceAromaFood ScienceFlavour and Fragrance Journal
researchProduct

A Programmable Networked Processing Node for 3D Brain Vessels Reconstruction

2011

Real-time 3D imaging represents a developing trend in medical imaging. However, most of the 3D medical imaging algorithms are computationally intensive. In this paper, a programmable networked node for 3D brain vessels reconstruction is proposed. Starting from 2D PC-MRA (Phase-Contrast Magnetic Resonance Angiography) sequences, the node is able to generate the 3D brain vasculature using the MIP (Maximum Intensity Projection) algorithm. The node has been prototyped on the Celoxica RC203E board, equipped with a Virtex II FPGA, to get the advantages of an hardware implementation, reaching a better throughput with respect to analogous software implementations. Its generality and programmable ca…

Settore ING-INF/05 - Sistemi Di Elaborazione Delle InformazioniVirtexbusiness.industryComputer scienceNode (networking)Iterative reconstructionDICOMMaximum intensity projectionMedical imagingMedical data processing 3D Brain Vessels Reconstruction embedded FPGA-based deviceComputer visionArtificial intelligenceField-programmable gate arraybusinessThroughput (business)Computer hardware
researchProduct

Infant crying: pattern of weeping, recognition of emotion and affective reactions in observers.

2012

This study has three objectives: a) to describe the main differences in the crying patterns produced by the three affective states most closely related to crying: fear, anger and pain; b) to study the adults' accuracy in the recognition of the affective states related to the infant's crying, and c) to analyze the emotional reaction that infant crying elicits in the observers. Results reveal that the main differences appear in the ocular activity and in the pattern of weeping. The infants maintain their eyes open during the crying produced by fear and anger, but in the case of crying provoked by painful stimuli, the eyes remain closed almost all the time. In regard to the pattern of weeping,…

AdultMaleendocrine systemLinguistics and Languagemedia_common.quotation_subjectEmotionsPainCryingAngerAngerLanguage and LinguisticsDevelopmental psychologyYoung AdultEmotional reactionmedicineHumansInfant cryingEyes openGeneral Psychologymedia_commonAgedMaximum intensityFacial expressionCryingSocial perceptionInfantRecognition PsychologyFearMiddle AgedFacial ExpressionSocial PerceptionInfant BehaviorFemalemedicine.symptomPsychologyThe Spanish journal of psychology
researchProduct

Helical computed tomographyangiography: Technical considerations and clinical applications

1997

Abstract A combination of volume acquisition techniques (helical CT), dedicated protocolsfor bolus injections of contrast medium, and postprocessing modalities have paved the way for computed tomography (CT) angiography. To obtain optimum results the collimation must be adapted to the vascular territory of interest, and the reconstruction of overlapping source images from the volume data set is advantageous for further postprocessing. Strong intravascular opacification is indispensable for the evaluation of vascular abnormalities and pathology and is also helpful for image postprocessing, where different modalities can be applied: multiplanar reconstruction, maximum intensity projection, se…

Aortamedicine.medical_specialtymedicine.diagnostic_testbusiness.industrymedicine.diseaseRenal artery stenosisPulmonary embolismStenosisContrast mediummedicine.arteryMaximum intensity projectionOcclusionAngiographymedicineRadiology Nuclear Medicine and imagingRadiologybusinessRadiography
researchProduct

Fatigue-related changes in technique emerge at different timescales during repetitive training

2017

Training consisting of numerous repetitions performed as closely as possible to ideal techniques is common in sports and every-day tasks. Little is known about fatigue-related technique changes that emerge at different timescales when repeating complex actions such as a karate front kick. Accordingly, 15 karatekas performed 600 kicks (1 pre-block and 9 blocks). The pre-block comprised 6 kicks (3 with each leg) at maximum intensity (K-100%). Each block comprised 60 kicks (10 with each leg) at 80% of their self-perceived maximum intensity (K-80%) plus 6 K-100%. In between blocks, the participants rested for 90 seconds. Right leg kinematics (peak joint angles, peak joint angular velocities, pe…

AdultMaleTime FactorsMovementPhysical ExertionPhysical Therapy Sports Therapy and RehabilitationKinematics03 medical and health sciences0302 clinical medicineHeart RateHumansOrthopedics and Sports MedicineLactic AcidJoint (geology)SimulationMathematicsMaximum intensityLegTraining (meteorology)030229 sport sciencesGeodesyBiomechanical PhenomenaDuration (music)Muscle FatigueFemalePerceptionMartial Arts030217 neurology & neurosurgeryPhysical Conditioning HumanJournal of Sports Sciences
researchProduct

Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: preoperative classification accuracy and histopathologic corre…

2012

Abstract Background To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as cont…

Malemedicine.medical_specialtyPerfusion ImagingHemodynamicsSensitivity and Specificity030218 nuclear medicine & medical imagingCorrelation03 medical and health sciences0302 clinical medicineImaging Three-DimensionalCortex (anatomy)Preoperative CaremedicineHumansRadiology Nuclear Medicine and imagingNeovascularization Pathologicbusiness.industryBrain NeoplasmsReproducibility of ResultsGeneral MedicineMiddle AgedPrognosisTumor BurdenCerebral blood volumemedicine.anatomical_structureMaximum intensity projectionBrain sizeCerebral hemisphereRadiographic Image Interpretation Computer-AssistedFemaleRadiologyNuclear medicinebusinessTomography X-Ray ComputedPerfusion030217 neurology & neurosurgeryAlgorithmsEuropean journal of radiology